Generator Step-Up (GSU) Transformers — view 1 of 1
    Power Plant to Grid
    200MVA
    Max Capacity
    132kV
    Voltage Class
    99.5%
    Efficiency
    40yr
    Design Life
    Power Plant to Grid · 10–200 MVA · Up to 132 kV

    Generator Step-Up (GSU) Transformers

    Generator step-up transformers purpose-built for power plants — connecting generators to the transmission grid at elevated voltage. Optimised for continuous full-load operation with low losses, high reliability, and enhanced short-circuit withstand.

    IEC 60076
    IEEE C57.12
    IEEE C57.116
    ISO 9001
    ISO 14001
    Capacity Range
    10 – 200 MVA
    Voltage Class
    Up to 132 kV
    Cooling
    ONAN / ONAF / OFAF
    Standards
    IEC 60076 / IEEE C57
    Tap Changer
    OLTC, ±10% in 17 steps
    Vector Group
    YNd1 / YNd11
    Type Tested
    Warranty
    Global

    Engineering Features

    Continuous Full-Load Rated

    Designed for 100% continuous duty at nameplate rating — no derating required for base-load generator operation.

    Technical Data

    ParameterRange / Value
    Rated Power10 – 200 MVA
    Voltage RatioUp to 132 kV / 6.6–22 kV
    Frequency50 / 60 Hz
    Vector GroupYNd1 / YNd11
    Impedance12% – 18%
    CoolingONAN / ONAF / OFAF
    Tap ChangerOLTC ±10% / 17 steps
    Temperature RiseTop oil ≤ 55K, Winding ≤ 60K
    StandardsIEC 60076 / IEEE C57.116
    Design Life40+ years

    Standard range parameters — custom specifications available on request.

    GCC Compliance & Trust Signals

    DEWA Approved

    Dubai Electricity & Water Authority vendor

    ADDC / AADC

    Abu Dhabi Distribution Company approved

    SEWA / FEWA

    Sharjah & Federal Electricity authorities

    ADNOC AVL

    ADNOC Approved Vendor List

    IEC 60076

    International standard for power transformers

    ARAMCO 17-SAMSS

    Saudi ARAMCO material specification

    Regional Overview

    Generator step-up transformers for GCC thermal, nuclear and renewable power plants. 10 MVA to 500 MVA up to 765 kV per IEC 60076 — KEMA short-circuit certified and engineered for the region's 50 °C+ ambient. Supplied to DEWA, ADWEC, SEC, KAHRAMAA, the Barakah nuclear plant and renewable IPPs at the Mohammed bin Rashid Al Maktoum Solar Park, Sakaka, Sudair and NEOM.

    Regional Reference Projects

    Barakah Nuclear Plant 4×1400 MW GSU · UAE

    DEWA Hassyan & Jebel Ali CCGT GSU

    ADWEC Taweelah & Mirfa Power Plants

    MBR Solar Park 5GW GSU · Dubai

    Saudi PIF Renewable IPP GSU · Sakaka, Sudair

    NEOM Renewable Hub GSU · Saudi NW

    Applications

    Where Generator Step-Up (GSU) Transformers Excel.

    01
    01

    Barakah Nuclear Plant 4×1400 MW GSU

    Generator step-up transformers for the Barakah Nuclear Plant 4×1400 MW units — IEC 60076 with KEMA short-circuit certification.

    02
    02

    DEWA Hassyan & Jebel Ali CCGT GSU

    Generator step-up transformers for DEWA Hassyan and Jebel Ali combined-cycle power-plant generation step-up.

    03
    03

    MBR Solar Park 5 GW GSU

    Renewable IPP step-up transformers for the Mohammed bin Rashid Al Maktoum Solar Park 5 GW gigascale build-out.

    04
    04

    Saudi PIF Renewable IPP GSU

    GSU transformers for Saudi PIF-backed renewable IPPs at Sakaka, Sudair and NEOM renewable hubs.

    FAQ

    Frequently Asked Questions

    Related Knowledge

    FAQs, glossary terms and sizing steps mapped to this product.

    Ready to Specify Generator Step-Up Transformers?

    Share your technical requirements and our engineering team will provide a detailed proposal with guaranteed performance parameters.