Earthing (Grounding) Transformers — view 1 of 1
    Neutral Grounding
    5MVA
    Max Rating
    36kV
    Voltage Class
    10s
    Short-Time Rating
    30yr
    Design Life
    Neutral Grounding · Zigzag / Star-Delta · Up to 36 kV

    Earthing (Grounding) Transformers

    Earthing transformers providing an artificial neutral point for unearthed or delta-connected MV systems — enabling reliable ground-fault detection, controlled fault clearance, and protection coordination in industrial and renewable networks.

    IEC 60076-6
    IEEE C57.12
    IEEE C57.32
    IEEE C62.92
    ISO 9001
    Rating
    50 kVA – 5 MVA
    Voltage Class
    Up to 36 kV
    Winding Configuration
    Zigzag / Star-Delta
    Standards
    IEC 60076-6 / IEEE C57
    Cooling
    ONAN / KNAN
    Short-Time Rating
    10 s typical
    Type Tested
    Warranty
    Global

    Engineering Features

    Zigzag or Star-Delta Winding

    Standard zigzag configuration for compact footprint, or star-delta with separate auxiliary winding when station service is required.

    Technical Data

    ParameterRange / Value
    Rated Power50 kVA – 5 MVA (continuous equivalent)
    System VoltageUp to 36 kV
    Frequency50 / 60 Hz
    Winding TypeZigzag (Z) / Star-Delta (YNd)
    Short-Time CurrentProject-specific (typ. 400–4000 A for 10 s)
    CoolingONAN / KNAN
    Insulation ClassBIL 75 / 125 / 170 kV per voltage class
    Auxiliary WindingOptional 230/400 V
    StandardsIEC 60076-6 / IEEE C57.32 / IEEE C62.92
    Design Life30+ years

    Standard range parameters — custom specifications available on request.

    US Compliance & Trust Signals

    IEEE C57.12

    ANSI/IEEE distribution transformer standard

    ANSI C57.12.00

    General requirements liquid-immersed

    DOE 2016

    US Department of Energy efficiency rule

    NEMA TR1

    Sound level & loss tolerances

    UL Listed

    Underwriters Laboratories safety mark

    IEEE C57.110

    Harmonic-loaded transformer rating

    Regional Overview

    Zigzag and Y-delta grounding transformers for North American utility, industrial and renewable service. 50 kVA to 5 MVA at up to 35 kV per IEEE C57.32 — providing artificial neutrals on ungrounded delta or IT systems and supporting NGR / NGR-bank fault-current limitation. Used at IPP solar and wind plants, industrial process facilities and US utility distribution.

    Regional Reference Projects

    ERCOT Solar & Wind IPP Grounding

    US Industrial Process Plants · IT System Earthing

    Hyperscale Data-Centre Grounding Transformers

    Petrochemical & Refining Plant Grounding

    Federal & DOE Site Grounding

    BESS Plant Neutral-Grounding · USA

    Applications

    Where Earthing (Grounding) Transformers Excel.

    01
    01

    ERCOT Solar & Wind IPP Grounding

    IEEE C57.32 zigzag grounding transformers for Texas and US renewable IPP collection-substation neutral-grounding.

    02
    02

    Hyperscale Data-Centre Grounding

    Y-delta grounding transformers for US hyperscale data-centre MV systems requiring artificial neutral and NGR fault-current limitation.

    03
    03

    Petrochemical & Refining Plants

    Grounding transformers for Gulf-Coast refining and petrochemical plants — IT-system neutral-grounding and NGR support.

    04
    04

    BESS Plant Neutral-Grounding USA

    Zigzag grounding transformers for US grid-scale BESS sites — IEEE C57.32 designed for cyclic bidirectional service.

    FAQ

    Frequently Asked Questions

    Ready to Specify Earthing Transformers?

    Share your technical requirements and our engineering team will provide a detailed proposal with guaranteed performance parameters.