Tested Beyond Standards.
    ISO/IEC 17025KEMA WitnessedMobile Labs

    Tested Beyond Standards.

    ISO/IEC 17025:2017 accredited laboratory with 40+ years of testing heritage — every test, every protocol, zero compromise.

    Contact Lab

    Our ISO/IEC 17025 accredited testing operations deliver IEEE C57.12.90 routine, type and short-circuit testing plus on-site DGA, FRA/SFRA and partial-discharge diagnostics for North American utilities, hyperscale data centres and industrial fleets — coordinated from Gaithersburg, MD.

    Regional Reference Projects

    PJM utility transformer DGA & condition-assessment

    Northern Virginia hyperscale fleet PD diagnostics

    ERCOT utility IEEE C57.12.90 routine FAT witnessing

    Gulf Coast refinery transformer FRA baseline survey

    Phoenix data-centre cluster oil-quality monitoring

    Federal infrastructure short-circuit certification reviews

    ISO/IEC 0
    Accreditation
    0+
    Tests Performed
    0+ yrs
    Years Experience
    0
    Field Failures
    Testing Scope

    Comprehensive Testing Services

    Full spectrum of electrical, thermal and mechanical tests for power, distribution, and dry-type transformers.

    Routine Tests

    Standard tests performed on every transformer before dispatch — ensuring compliance with rated specifications.

    Winding resistance
    Turns ratio & polarity
    Impedance voltage
    No-load loss & current
    Load losses
    Applied voltage test

    Type Tests

    Design validation tests demonstrating compliance with standard requirements on a representative unit.

    Temperature rise test
    Lightning impulse (BIL)
    Switching impulse
    Short-circuit withstand
    Sound level measurement
    Partial discharge (PD)

    Special Tests

    Advanced diagnostic tests for critical installations and fleet condition assessments.

    Frequency Response (FRA)
    Dissolved Gas Analysis
    Sweep Frequency (SFRA)
    Tan delta & power factor
    Thermal imaging
    Zero-sequence impedance

    Condition Assessment

    Comprehensive health evaluation for ageing transformers — data-driven decisions on repair, refurbish or replace.

    Oil quality analysis
    Insulation assessment
    Bushing condition
    OLTC diagnostics
    Cooling system review
    Remaining life estimation
    Testing Process

    Rigorous Test Protocol

    A structured testing protocol ensuring every measurement is accurate, traceable and documented.

    01

    Test Planning

    Define test scope, standards, witness requirements and acceptance criteria.

    02

    Instrumentation Setup

    Calibrated instruments, safety barriers and environmental conditioning.

    03

    Thermal Testing

    Temperature rise, hot-spot measurement and cooling performance verification.

    04

    Electrical Testing

    Impulse, applied voltage, induced voltage and partial discharge measurements.

    05

    Analysis & Reporting

    Data analysis, compliance verification and comprehensive test report preparation.

    06

    Certification

    Issue accredited test certificates with full traceability to international standards.

    Accredited Laboratory

    Our Dubai testing laboratory holds ISO/IEC 17025:2017 accreditation — the highest standard for test laboratory competence and impartiality.

    • ISO/IEC 17025:2017 accredited
    • 2,000 kV impulse generator
    • 400 kV class test capacity
    • KEMA-witnessed test protocols

    On-Site Testing

    Mobile testing units deployed to your site for commissioning verification, condition assessment, and fleet health surveys.

    48h
    Deployment Time
    3
    Mobile Test Units
    IEC
    Standards Compliance
    100%
    Report Delivery
    Request On-Site Testing

    Need Testing Services?

    Our accredited laboratory and mobile testing units are available for routine, type and special tests.

    All Services