Medium Power Transformers — view 1 of 12
    Oil Immersed
    150MVA
    Max Capacity
    220kV
    Voltage Class
    99.5%
    Efficiency
    40yr
    Design Life
    Oil Immersed · Custom-Engineered

    Medium Power Transformers

    Up to 150 MVA — every power transformer is custom-designed to your system requirements, type-tested to IEC 60076 or ANSI/IEEE C57, and backed by KEMA-certified short-circuit withstand capability.

    IEC 60076
    IEEE C57
    KEMA
    ISO 9001
    ISO 14001
    Capacity Range
    Up to 150 MVA
    Voltage Class
    Up to 220 kV
    Cooling Methods
    ONAN / KNAN / ONAF / KNAF / ODAF / OFAF
    Standards
    IEC 60076 / IEEE C57
    Insulation
    Oil Immersed (Mineral / Ester)
    Core Design
    Step-Lap Mitre Grain-Oriented
    Type Tested
    Warranty
    Global

    Engineering Features

    KEMA Short-Circuit Testing

    KEMA-witnessed short-circuit withstand testing for proven reliability under fault conditions.

    Technical Data

    ParameterRange / Value
    Rated PowerUp to 150 MVA
    Primary VoltageUp to 220 kV
    Secondary Voltage6.6 – 36 kV
    Frequency50 / 60 Hz
    Impedance8% – 14% (customizable)
    Vector GroupAs per specification
    Noise Level≤ 70 dB(A) at 1m
    Total LossesPer IEC/IEEE guaranteed values
    Temperature RiseTop oil ≤ 60K, Winding ≤ 65K
    Insulation LevelFull BIL / SIL as per class

    Standard range parameters — custom specifications available on request.

    US Compliance & Trust Signals

    IEEE C57.12

    ANSI/IEEE distribution transformer standard

    ANSI C57.12.00

    General requirements liquid-immersed

    DOE 2016

    US Department of Energy efficiency rule

    NEMA TR1

    Sound level & loss tolerances

    UL Listed

    Underwriters Laboratories safety mark

    IEEE C57.110

    Harmonic-loaded transformer rating

    Regional Overview

    IEEE C57.12.00 / ANSI C57 compliant medium power transformers for North American transmission and sub-transmission service. From 5 MVA through 150 MVA at 69 kV, 138 kV, 161 kV and 230 kV, every unit is DOE 2016 efficient, KEMA short-circuit certified and seismic-qualified. We support investor-owned utilities, Independent Power Producers, NRECA G&T co-operatives and hyperscale data-centre operators from our Gaithersburg, Maryland office.

    Regional Reference Projects

    East-Coast IOU Sub-Transmission · 69/138 kV

    ERCOT & PJM Generator Step-Up · IPP Wind & Solar

    Hyperscale Data-Centre Bulk Power · Northern Virginia

    NRECA G&T Co-operatives · Midwest Transmission

    Industrial Power Plants · Refining & Petrochemical

    Public-Power Authorities · TVA, BPA Service

    Applications

    Where Medium Power Transformers Excel.

    01
    01

    ERCOT, PJM & MISO Substations

    IEEE C57.12 sub-transmission transformers for ERCOT, PJM, MISO and SPP substation upgrades and capacity expansion.

    02
    02

    Combined-Cycle GSU Duty

    ANSI/IEEE generator step-up transformers for combined-cycle gas plants and peaking facilities across the US.

    03
    03

    Utility-Scale Renewables (US)

    IEEE C57.159 collector and grid-tie transformers for utility-scale solar, wind and BESS interconnections.

    04
    04

    Hyperscale Data Centre Primary Feeds

    138 kV / 69 kV primary feed transformers for hyperscale data-centre campuses requiring redundant utility supply.

    FAQ

    Frequently Asked Questions

    Ready to Specify Medium Power Transformers?

    Share your technical requirements and our engineering team will provide a detailed proposal with guaranteed performance parameters.