Cast Resin Dry Type Transformers — view 1 of 8
    Epoxy Cast
    25MVA
    Max Capacity
    F1
    Fire Class
    -25°C
    Min Ambient
    0Oil
    Zero Risk
    Epoxy Cast · Fire Safe · Zero Oil

    Cast Resin Dry Type Transformers

    Epoxy vacuum-cast resin transformers with F1 moisture class and C2 climate classification. Designed for environments where oil-free operation is critical — hospitals, data centers, marine, metro systems, and high-rise buildings.

    IEC 60076-11
    ISO 9001
    ISO 14001
    DNV (optional)
    Capacity Range
    100 kVA – 25 MVA
    Voltage Class
    Up to 36 kV
    Cooling
    AN / AF (Air Natural/Forced)
    Standards
    IEC 60076-11
    Enclosure
    IP31 / IP54
    Climate Class
    C2 (-25°C)
    Installation Support available on request
    Support from an ETS engineer during installation and commissioning, available on request.
    Type Tested
    Warranty
    Global

    Engineering Features

    Zero Oil Design

    Eliminates fire and environmental contamination risk — no oil containment needed.

    Technical Data

    ParameterRange / Value
    Rated Power100 kVA – 25 MVA
    Primary Voltage6.6 – 36 kV
    Secondary Voltage230/400 V – 690 V
    Frequency50 / 60 Hz
    Impedance4% – 6%
    Insulation ClassF (155°C)
    Partial Discharge< 10 pC at 1.6 × Un
    Noise Level≤ 55 dB(A)
    Overload (AF)+40% with forced cooling
    EnclosureIP00 to IP54

    Standard range parameters — custom specifications available on request.

    US Compliance & Trust Signals

    IEEE C57.12

    ANSI/IEEE distribution transformer standard

    ANSI C57.12.00

    General requirements liquid-immersed

    DOE 2016

    US Department of Energy efficiency rule

    NEMA TR1

    Sound level & loss tolerances

    UL Listed

    Underwriters Laboratories safety mark

    IEEE C57.110

    Harmonic-loaded transformer rating

    Regional Overview

    Cast-resin dry-type transformers for US indoor and zero-oil environments — hyperscale data centers, healthcare, educational facilities and high-rise commercial. Up to 25 MVA at 35 kV, UL 1562 listed and tested to IEEE C57.12.01 / NEMA TR1. F1 fire class, K-rated for harmonic loading, with NEMA 1 / NEMA 3R / NEMA 4 enclosures available.

    Applications

    Where Cast Resin Dry Type Transformers Excel.

    01
    01

    Northern Virginia & Phoenix Data Centers

    Cast resin transformers for hyperscale Tier III/IV data-center halls in Northern Virginia, Dallas, Phoenix and Hillsboro.

    02
    02

    US Hospitals & Healthcare

    F1 fire-class dry-type transformers for major hospital systems and healthcare campuses across the United States.

    03
    03

    Subway & Mass Transit

    Cast resin transformers for NYC Subway, MBTA, WMATA and other US metro / mass-transit electrification projects.

    04
    04

    US High-Rise & Commercial Towers

    Zero-oil transformers for Class-A office towers, hotels and mixed-use developments in NYC, Chicago, Miami and LA.

    FAQ

    Frequently Asked Questions

    Ready to Specify Cast Resin Dry Type Transformers?

    Share your technical requirements and our engineering team will provide a detailed proposal with guaranteed performance parameters.