Mobile Transformers — view 1 of 4
    Trailer-Mounted
    5MVA
    Max Rating
    33kV
    Voltage Class
    100%
    Factory Tested
    30yr
    Design Life
    Trailer-Mounted · Rapid Response · Up to 33 kV

    Mobile Transformers

    Trailer-mounted mobile substation transformers engineered for rapid network restoration and temporary supply during planned and unplanned outages. Up to 5 MVA at 33 kV — deployable by road within hours by a small commissioning crew.

    IEC 60076
    BS EN 60076
    ISO 9001
    Rating
    Up to 5 MVA
    Voltage Class
    Up to 33 kV
    Cooling
    ONAN
    Standards
    BS EN 60076 / IEC 60076
    Tap Changer
    DETC ±2 × 2.5%
    Enclosure
    Outdoor IP54 / road-rated
    Installation Support available on request
    Support from an ETS engineer during installation and commissioning, available on request.
    Type Tested
    Warranty
    Global

    Engineering Features

    Trailer-Mounted for Rapid Road Deployment

    Mounted on a road-going trailer (≤ 44 t GVW) with integrated jacks and tie-downs — deployable to site by road and energised within hours of arrival.

    Technical Data

    ParameterRange / Value
    Rated PowerUp to 5 MVA
    System VoltageUp to 33 kV
    Frequency50 / 60 Hz
    CoolingONAN
    Insulation FluidMineral oil (ester optional)
    Insulation ClassPer voltage class
    Tap ChangerDETC ±2 × 2.5%
    EnclosureOutdoor IP54 / road-rated
    StandardsBS EN 60076 / IEC 60076 / ISO 9001
    Design Life30+ years

    Standard range parameters — custom specifications available on request.

    US Compliance & Trust Signals

    IEEE C57.12

    ANSI/IEEE distribution transformer standard

    ANSI C57.12.00

    General requirements liquid-immersed

    DOE 2016

    US Department of Energy efficiency rule

    NEMA TR1

    Sound level & loss tolerances

    UL Listed

    Underwriters Laboratories safety mark

    IEEE C57.110

    Harmonic-loaded transformer rating

    Regional Overview

    Trailer-mounted mobile substation transformers for US utility, industrial and disaster-response service. Up to 5 MVA at 34.5 kV per IEEE C57.12 — deployable by road within hours for rapid network restoration after storm damage, transformer failure or wildfire, and for planned outage cover at utility, mining and construction sites across North America.

    Applications

    Where Mobile Transformers Excel.

    01
    01

    Emergency Network Restoration

    Mobile emergency substations for rapid restoration after transformer failure, fire damage or flood at primary and secondary substations.

    02
    02

    Planned & Unplanned Outage Cover

    Temporary power for planned substation refurbishment, transformer replacement projects and unplanned outage contingencies.

    03
    03

    Event & Construction Temporary Supply

    Temporary MV/LV supply for large construction projects, mining camps and major events where permanent infrastructure is not yet available.

    04
    04

    DNO Contingency Fleets

    Strategic spares held by Distribution Network Operators and large industrial estates as part of disaster-response and resilience plans.

    FAQ

    Frequently Asked Questions

    Ready to Specify Mobile Transformers?

    Share your technical requirements and our engineering team will provide a detailed proposal with guaranteed performance parameters.