Earthing Transformers — view 1 of 1
    Neutral Earthing
    5MVA
    Max Rating
    36kV
    Voltage Class
    10s
    Short-Time Rating
    30yr
    Design Life
    Neutral Earthing · Zigzag / Star-Delta · Up to 36 kV

    Earthing Transformers

    Earthing transformers providing an artificial neutral point for unearthed or delta-connected MV systems — enabling reliable ground-fault detection, controlled fault clearance, and protection coordination in industrial and renewable networks.

    IEC 60076-6
    IEEE C57.12
    IEEE C57.32
    IEEE C62.92
    ISO 9001
    Rating
    50 kVA – 5 MVA
    Voltage Class
    Up to 36 kV
    Winding Configuration
    Zigzag / Star-Delta
    Standards
    IEC 60076-6 / IEEE C57
    Cooling
    ONAN / KNAN
    Short-Time Rating
    10 s typical
    Installation Support available on request
    Support from an ETS engineer during installation and commissioning, available on request.
    Type Tested
    Warranty
    Global

    Engineering Features

    Zigzag or Star-Delta Winding

    Standard zigzag configuration for compact footprint, or star-delta with separate auxiliary winding when station service is required.

    Technical Data

    ParameterRange / Value
    Rated Power50 kVA – 5 MVA (continuous equivalent)
    System VoltageUp to 36 kV
    Frequency50 / 60 Hz
    Winding TypeZigzag (Z) / Star-Delta (YNd)
    Short-Time CurrentProject-specific (typ. 400–4000 A for 10 s)
    CoolingONAN / KNAN
    Insulation ClassBIL 75 / 125 / 170 kV per voltage class
    Auxiliary WindingOptional 230/400 V
    StandardsIEC 60076-6 / IEEE C57.32 / IEEE C62.92
    Design Life30+ years

    Standard range parameters — custom specifications available on request.

    UK Compliance & Trust Signals

    ENATS 35-1

    DNO-approved distribution transformer specification

    ENATS 35-2

    UK secondary substation transformer standard

    G99 Compliant

    Engineering Recommendation G99 grid interface

    BS EN 60076

    British Standard for power transformers

    EcoDesign Tier 2

    EU 548/2014 efficiency compliance

    Regional Overview

    Zigzag and star-delta earthing transformers for UK & Ireland utility, industrial and renewable service. 50 kVA to 5 MVA at up to 36 kV per BS EN 60076-6, providing an artificial neutral on unearthed delta or IT systems. Used with neutral-earthing resistors (NER) and reactors for fault-current limitation in DNO secondary distribution, renewable plants and industrial process power.

    Applications

    Where Earthing Transformers Excel.

    01
    01

    UK Renewable IPP Earthing

    Zigzag earthing transformers providing artificial neutral on UK solar and wind farm collection systems for G99 grid-code compliance.

    02
    02

    DNO Distribution Network Earthing

    BS EN 60076-6 zigzag transformers for UK distribution network operator neutral-earthing on unearthed delta systems including UKPN, NIE Networks, Scottish Power and SSE frameworks.

    03
    03

    Industrial IT-System Earthing

    Star-delta earthing transformers for UK industrial process plants requiring artificial neutral on IT or unearthed systems.

    04
    04

    BESS Site Neutral-Earthing

    Earthing transformers for UK Battery Energy Storage System sites — paired with NER for fault-current limitation and grid compliance.

    FAQ

    Frequently Asked Questions

    Ready to Specify Earthing Transformers?

    Share your technical requirements and our engineering team will provide a detailed proposal with guaranteed performance parameters.