Cast Resin Dry Type Transformers
Epoxy vacuum-cast resin transformers with F1 moisture class and C2 climate classification. Designed for environments where oil-free operation is critical — hospitals, data centres, marine, metro systems, and high-rise buildings.
Engineering Features
Zero Oil Design
Eliminates fire and environmental contamination risk — no oil containment needed.
Technical Data
| Parameter | Range / Value |
|---|---|
| Rated Power | 100 kVA – 25 MVA |
| Primary Voltage | 6.6 – 36 kV |
| Secondary Voltage | 230/400 V – 690 V |
| Frequency | 50 / 60 Hz |
| Impedance | 4% – 6% |
| Insulation Class | F (155°C) |
| Partial Discharge | < 10 pC at 1.6 × Un |
| Noise Level | ≤ 55 dB(A) |
| Overload (AF) | +40% with forced cooling |
| Enclosure | IP00 to IP54 |
Standard range parameters — custom specifications available on request.
Related glossary terms
ENATS 35-1
DNO-approved distribution transformer specification
ENATS 35-2
UK secondary substation transformer standard
G99 Compliant
Engineering Recommendation G99 grid interface
BS EN 60076
British Standard for power transformers
EcoDesign Tier 2
EU 548/2014 efficiency compliance
Cast-resin dry-type transformers engineered for UK indoor and oil-free environments — data centres, hospitals, high-rise residential and underground stations. Up to 25 MVA at 36 kV with F1 fire-resistance, C2 climatic and E2 environmental classification per BS EN 60076-11. Aluminium or copper foil windings, IP31 / IP54 enclosures and partial-discharge tested below 10 pC.
Where Cast Resin Dry Type Transformers Excel.
UK Hospitals & NHS Estate
F1 fire-class cast resin transformers for NHS hospitals, healthcare campuses and life-science facilities across the UK.
London & Manchester Data Centres
Zero-oil cast resin transformers for Tier III/IV data-centre campuses across Slough, Docklands, Manchester and Cardiff.
UK Rail & Underground
Cast resin transformers for London Underground, Crossrail/Elizabeth Line, HS2 and Network Rail station infrastructure.
UK High-Rise & Mixed-Use
F1-rated dry-type transformers for City of London skyscrapers, Battersea, Stratford and major mixed-use schemes.
Frequently Asked Questions
Related engineering tools
Specify, size, and validate this transformer with our free engineering calculators — used by EPCs and consultants worldwide.
Related Knowledge
FAQs, glossary terms and sizing steps mapped to this product.

Ready to Specify Cast Resin Dry Type Transformers?
Share your technical requirements and our engineering team will provide a detailed proposal with guaranteed performance parameters.