Cast Resin Dry Type Transformers — view 1 of 8
    Epoxy Cast
    25MVA
    Max Capacity
    F1
    Fire Class
    -25°C
    Min Ambient
    0Oil
    Zero Risk
    Epoxy Cast · Fire Safe · Zero Oil

    Cast Resin Dry Type Transformers

    Epoxy vacuum-cast resin transformers with F1 moisture class and C2 climate classification. Designed for environments where oil-free operation is critical — hospitals, data centres, marine, metro systems, and high-rise buildings.

    BS EN 61936-1
    EU EcoDesign Tier 2
    IEC 60076-11
    ISO 9001
    ISO 14001
    DNV (optional)
    Capacity Range
    100 kVA – 25 MVA
    Voltage Class
    Up to 36 kV
    Cooling
    AN / AF (Air Natural/Forced)
    Standards
    IEC 60076-11
    Enclosure
    IP31 / IP54
    Climate Class
    C2 (-25°C)
    Installation Support available on request
    Support from an ETS engineer during installation and commissioning, available on request.
    Type Tested
    Warranty
    Global

    Engineering Features

    Zero Oil Design

    Eliminates fire and environmental contamination risk — no oil containment needed.

    Technical Data

    ParameterRange / Value
    Rated Power100 kVA – 25 MVA
    Primary Voltage6.6 – 36 kV
    Secondary Voltage230/400 V – 690 V
    Frequency50 / 60 Hz
    Impedance4% – 6%
    Insulation ClassF (155°C)
    Partial Discharge< 10 pC at 1.6 × Un
    Noise Level≤ 55 dB(A)
    Overload (AF)+40% with forced cooling
    EnclosureIP00 to IP54

    Standard range parameters — custom specifications available on request.

    UK Compliance & Trust Signals

    ENATS 35-1

    DNO-approved distribution transformer specification

    ENATS 35-2

    UK secondary substation transformer standard

    G99 Compliant

    Engineering Recommendation G99 grid interface

    BS EN 60076

    British Standard for power transformers

    EcoDesign Tier 2

    EU 548/2014 efficiency compliance

    Regional Overview

    Cast-resin dry-type transformers engineered for UK indoor and oil-free environments — data centres, hospitals, high-rise residential and underground stations. Up to 25 MVA at 36 kV with F1 fire-resistance, C2 climatic and E2 environmental classification per BS EN 60076-11. Aluminium or copper foil windings, IP31 / IP54 enclosures and partial-discharge tested below 10 pC.

    Applications

    Where Cast Resin Dry Type Transformers Excel.

    01
    01

    UK Hospitals & NHS Estate

    F1 fire-class cast resin transformers for NHS hospitals, healthcare campuses and life-science facilities across the UK.

    02
    02

    London & Manchester Data Centres

    Zero-oil cast resin transformers for Tier III/IV data-centre campuses across Slough, Docklands, Manchester and Cardiff.

    03
    03

    UK Rail & Underground

    Cast resin transformers for London Underground, Crossrail/Elizabeth Line, HS2 and Network Rail station infrastructure.

    04
    04

    UK High-Rise & Mixed-Use

    F1-rated dry-type transformers for City of London skyscrapers, Battersea, Stratford and major mixed-use schemes.

    FAQ

    Frequently Asked Questions

    Ready to Specify Cast Resin Dry Type Transformers?

    Share your technical requirements and our engineering team will provide a detailed proposal with guaranteed performance parameters.